Ice Maker Line Installation in San Diego
- Home
- /
- Ice Maker Line Installation in San Deigo
The water line to a refrigerator is a quarter-inch tube that stays under pressure every hour of the day, usually in a spot nobody looks at for years. A good install depends less on the tube than on its two ends: where it taps into the house’s cold water and what kind of valve controls it. One customer of ours needed a new valve before a new fridge could go in, and wanted to add an ice maker at the same time. We replaced the valve, and the finished hookup was a recessed box in the wall behind the fridge, with a copper stub and a quarter-turn shutoff sitting inside it.
Where the Water Comes From
Every ice maker line starts at a cold water pipe. GE’s installation guide shows the usual routes: from the cold line under the kitchen sink, through a wall from a utility room, or up through the floor from below.
The cold line under the sink
The sink’s cold supply is the nearest pipe in most kitchens. We add a tee with its own shutoff, so the fridge can be turned off without losing water at the faucet. The tubing then runs through the cabinet side or the floor to the fridge space.
A recessed box behind the fridge
An outlet box puts the valve in the wall directly behind the refrigerator. The fridge can stand closer to the wall, and you reach the shutoff by rolling the fridge forward, not by emptying a sink cabinet. It does mean opening the drywall and running pipe to the box, so it’s the common pick during a remodel or when the fridge is far from the sink.
Another pipe close by
Sometimes a cold line already runs in the wall next to the fridge space, such as laundry valves on the other side. A short run from a sound pipe beats a long one across the kitchen. Wherever we tap in, GE’s guide says to connect on the top or side of a horizontal pipe, never the bottom, so the line doesn’t pull in sediment.
Why We Don’t Use Saddle Valves
Many store kits include a saddle valve, a clamp that bolts around the pipe with a rubber washer and a pin that pierces it. GE’s own support page doesn’t recommend the self-piercing kind. The opening is too small, and restricted flow means small cubes, hollow cubes and slow ice production. GE’s installation guide also says to confirm a saddle valve meets your local plumbing code before you buy one.
We cut in a proper tee and a quarter-turn shutoff instead. Under one customer’s bathroom sink, the old shutoff was plastic and had cracked, and we replaced it with a brass ball-style valve. There’s a money reason as well: GE’s warranty covers manufacturing defects only, and it doesn’t cover problems caused by improperly installed plumbing or the wrong parts.
What the Line Should Be Made Of
Line | What to know |
Copper, 1/4 inch outside diameter | What GE’s guide calls for, with a compression nut and ferrule at each end. Lasts for decades, but kinks if it’s bent too tightly. |
PEX | Flexible and won’t corrode. Needs fittings made for it and support along its route. |
Braided stainless connector | Common for the last few feet to the fridge, and quick to swap if it’s ever damaged. |
Plain plastic tubing | GE says not to use it: the line is under pressure all the time, and some plastic tubing turns brittle with age and cracks. |
Leave slack behind the fridge. GE calls for about 8 extra feet of copper, coiled into three loops roughly 10 inches across. That lets the refrigerator roll out without straining the connection. Place the coil where it won’t rattle against the wall.
Check the House Pressure First
GE’s ice makers accept 20 to 120 psi at the inlet. The California Plumbing Code is stricter about the house itself: above 80 psi, the home needs a pressure regulator. Small valves and compression fittings take the worst of high pressure. We saw that when a toilet supply line and its plastic nut burst while the owners were out of town and water reached the floor below. The house was running at 110 psi, so new valves alone weren’t the whole fix; the regulator needed attention too. If faucets bang when they shut off, have the pressure tested when the fridge line goes in. Our pressure regulator page explains how we test it and what replacement involves.
The First Day After Hookup
- Flush the new line. Before the fridge end is connected, GE has you run water through the tubing until it’s clear, about a quart, then shut it off.
- Check each fitting with the water on. A compression nut that’s going to weep usually shows it within minutes. Tighten any that do.
- Give the freezer time. GE allows about 24 hours for a newly installed freezer to get cold enough to make ice.
- Toss the first few batches. GE says to throw them away to flush the last impurities out of the new line.
One repeat customer has had us install faucets, swap angle stops and hook up the fridge’s ice maker over a few visits. If your line is already in and leaking, or the dispenser only trickles, that’s a repair, and our ice maker line repair page covers tracking down where it’s failing.
To book an install, call (858) 567-0544 any weekday from 8 AM until 5 PM. Tell us where the fridge sits compared with the sink and if you’d like a wall box, or send a photo of the space through Contact Us. Every job runs under our state license, CSLB #910268, and under master plumber Tony Misleh, who founded the company in 2007.